Power Source
230 V AC, 50/60 Hz
Power Consumption
850 W (with rated output signal), 380 W (according to EN62368-1)
Rated Output
360 W
Frequency Response
50 Hz – 20 kHz, ±3 dB (at 1/3 rated output)
Distortion
0.7 % or less (at rated output, 1 kHz)
S/N Ratio
85 dB or more
Audio Input/Output Characteristic
Sampling frequency: 48 kHz
A/D D/A converter: 24 bit
Input
Input 1 – 3: -50 dB* (MIC)/-10 dB* (LINE) (changeable), 600 Ω,
electronically balanced, combined XLR connector (female)/phone jack
Input 4: -50 dB* (MIC)/-10 dB* (LINE) (changeable), 600 Ω, electronically balanced,
removable terminal block (14 pins)
BGM 1 – 2: -10 dB*, 10 kΩ, unbalanced, RCA pin jack
External amplifier input: 100 V line, removable terminal block (14 pins)
Output
Speaker output 1 – 2: Max. (360 W) per output
Speaker output 3 – 6: Max. (120 W) per output
Speaker output 1 – 6: Total within 360 W, removable terminal block (14 pins)
Allowable minimum load: 500 Ω (20 W) at 100 V line for speaker line failure detection
Direct output: Direct output from internal or external amplifier,
removable terminal block (16 pins)
Recording output BGM/Paging: 0 dB*, 10 kΩ, unbalanced, RCA pin jack
RM Link
Input 1 – 2: Connecting the RM-300MF/RM-200M Remote Microphone.
RJ45 female connector
Maximum distance: Total 800 m (874.89 yd) between this unit and remote microphones
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
Network I/F
10BASE-T / 100BASE-TX (selectable by automatic negotiation), RJ45 female connector
Maximum distance: 100 m (109.36 yd) between this unit and a switching hub
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
VM Link
Output: Connecting the VM-3240E or VM-3360E, RJ45 female connector
Maximum distance: 800 m (874.89 yd)
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
EXT PA Link
Connecting the VP-2421, RJ45 female connector
Maximum distance: 5 m (16.4 ft)
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
General Control
Input 1 – 8: No-Voltage make contact input, open voltage: 24 V DC,
short-circuit current: 2 mA or less, removable terminal block (14 pins)
Output 1 – 8: Isolated open collector output, withstand voltage: 30 V DC,
operating current: 10 mA or less, removable terminal block (14 pins)
Emergency Control
Input 1 – 5: No-Voltage make contact input, open voltage: 24 V DC,
short-circuit current: 2 mA or less, RJ45 female connector
Input 6: Isolated voltage input, Inactive: -24 V ±20 %, Active: +24 V ±20 %,
RJ45 female connector
Status out: Relay contact output, withstand voltage: 40 V DC,
operating current: 2 – 300 mA, RJ45 female connector
ATT Control
Relay contact 1-6, 125 V AC or 30 V DC, total under 5 A,
removable terminal block (16 pins)
Power Input/Output
Power in: Connecting the VX-2000DS only (operating range: 20 – 40 V DC)
PS out: 28 V DC/24 A
M4 screw terminal, distance between barriers: 11 mm (0.43″)
DC24V Output
24 V DC, Maximum feeding current 0.3 A
Ds Link
Connecting the VX-2000DS, RJ45 female connector
Maximum distance: 5 m (16.4 ft)
Link cable: Category 5 Shielded Twisted-Pair straight cable (CAT5-STP)
Operating Temperature
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
Operating Humidity
5 % to 95 %RH (no condensation)
Finish
Panel: Aluminum, hairline, black
Case: Surface-treated steel plate, black, paint
Dimensions
482 (W) × 132.6 (H) × 431.2 (D) mm (18.98″ × 5.22″ × 16.98″)
Weight
19 kg (41.89 lb)
Accessory
Power cable (2 m (6.56 ft)) …1, Setting software-CD …1, Link cable (3 m (9.84 ft)) …2, Removable terminal plug (14 pins)…3, Removable terminal plug (16 pins) …1, Emergency microphone (hand-held type) …1
Option
Input transformer: IT-450