Power Source
AC: 230 V
DC: 24 V/7.5 A
Applicable cable diameter: AWG22 – AWG14
Power Consumption on AC Mains
With no signal present: 37 W
Under normal operating conditions according to
EN60065: 1998 sec. 4.2: 107 W
With rated output signal: 201 W
Current Consumption on 24 V DC Power Input
With no signal present: 0.7 A
Under normal operating conditions according to
EN60065: 1998 sec. 4.2: 2.1 A
With rated output signal: 5.2 A
Rated Output
120 W
Output Voltage /Impedance
100 V/83 Ω
(selectable by the internal wiring change)
Frequency Response
50 Hz – 16 kHz
Distortion
1 % or less
Signal-to-Noise Ratio
60 dB or more
Tone Control
Bass: 100 Hz ±10 dB
(Inputs 1 – 3 and BGM individually adjustable.)
Remote Microphone /Expansion Amplifier Connection
2 RJ45 female connectors for connecting the RM-200M Remote
Microphone and the VM-2120 or VM-2240 unit used as an
expansion amplifier.
Maximum distance: 800 m (874.89 yd) in total
Link cable: Category 5 Shielded
Number of connectable RM-200M’s: Up to 4
Twisted-Pair straight cable (TIA/EIA-568A standard)
Input
Inputs 1 – 3: -60 dB(*3) (MIC)/-10 dB(*3) (LINE) (changeable)
600 Ω
combined XLR connector (female)/phone jack
(Only Input 1 is additionally equipped with DIN
connector(*5).)
Telephone paging input: Push-in terminal block(*6)
Voice sound: -10 dB(*3)
balanced input with shield terminal(*4)
Control: No-voltage make contact input
open voltage: 3.3 V DC
short-circuit current: under 1 mA
BGM 1 – 2: -20 dB(*3)
Power amplifier input: 0 dB(*3)
External speaker line input: 100 V line
(This input is selected when the “Unit’s
broadcast cutoff” control is activated.)
Output
Speaker output: Plug-in screw connector(*7)
5-zone selector with attenuator (all zones simultaneously
selectable)
Direct speaker line output: Direct output from the power amplifier
output transformer (attenuator bypassed)
Plug-in screw connector(*7)
Line output: 0 dB(*3)
Recording output: 0 dB(*3)
Preamplifier output: 0 dB(*3)
Control Input
For controlling Inputs 1 – 3
No-voltage make contact input
short-circuit current: 1 mA or less
Control Input and Output
D-sub connector (25-pin
Input: No-voltage make contact input
short-circuit current: 1 mA or less
Output: Open collector output
control current: 10 mA or less
(1) External control input
Activation of messages(*8)
Activation of power
Activation and stop of Emergency Broadcast
Unit’s broadcast cutoff
(when activated by an external emergency equipment)
(2) Status output
Irregularity of communications with the Remote Microphone and
an expansion amplifier
AC power condition
DC power condition
Irregularity of the sound source of the Voice Announcement Board
Failure (FAULT) indication on
Power switch o
External Attenuator Control Output
Plug-in screw connector(*7)
transfer type
contact current: 7 A (DC) or less
Surveillance Input and Output(*9)
D-sub connector (25-pin
Input: No-voltage make contact input
Output: Open collector output
Power Supply
24 V DC/0.1 A
Unit RU-2001/-2002
Chime Tone
Built-in chime: 2-tone chime/2-tone chime (fast repeat)/4-tone
chime (Up)/Single-tone chime/4-tone chime (Up &
Down)/Gong/off
Voice Announcement Board sound source: Pre-recorded chime(*8)
Function
Two units stacking (VM-2120 or VM-2240)
Emergency broadcast (sequential control)
Broadcast priority control
Surveillance (failure detection) function(*9)
Power supply to only one Remote Microphone (RM-200M)
Line resistance: 40 Ω (one way) or less
Operating Temperature
0 ℃ to +40 ℃ (32 %%dF to 104 %%dF)
Finish
Panel: ABS resin
Case: Steel plate
Dimensions
419 (W) × 143.3 (H) × 355.7 (D) mm (16.5 × 5.64″ × 14)
Weight
12.5 kg (27.56 lb)
Accessory
Power cable (2 m (6.56 ft)) ……1
Miniature type time-lag fuse T2.5 A ……1
Option
Rack mounting bracket: MB-36
Input transformer: IT-450
Voice announcement board: EV-200M
Surveillance board: SV-200MA
TMV INTER TRADING บริษัทผู้จัดจำหน่ายระบบรักษาความปลอดภัย ราคาส่ง ถูกที่สุด